The new energy electric vehicle charging and discharging tester verifies whether new energy vehicles can effectively establish communication and interaction with different charging facilities, networks, and systems, thereby enabling convenient, fast, safe, and reliable charging services. The system performs routine charging tests, abnormal charging state tests, and discharge power detection.
■ Multi-standard compatibility: Supports national and European standards for AC/DC charging and AC discharge testing.
■ CAN communication control: Supports CAN bus data interaction and remote control.
■ Intelligent temperature control: Automatically adjusts fan speed according to equipment temperature.
■ Flexible power regulation: Supports voltage regulation, current limiting, and current sharing functions.
■ Comprehensive protection mechanism: It has high- and low-temperature protection, over- and under-voltage protection, three-phase imbalance protection, overvoltage protection, and short-circuit protection.
■ Data retention after power failure: Supports storage of group number and hardware address after power failure.
It integrates multi-standard charge and discharge testing, CAN communication control, intelligent adjustment, multiple safety protections and data storage, providing reliable testing support for the charging and discharging functions and charging interoperability verification of new energy vehicles.
Specifications of Charging and Discharging Testing Equipment for New Energy Electric Vehicles
| Project | Specification |
| Equipment power supply | AC380V±10% 50Hz |
| Ambient temperature | -5~40℃ |
| Ambient humidity | Not exceeding 75% RH (no water vapor condensation) |
| Equipment size | 800*800*1750 (W*D*H excluding air conditioning) |
| Equipment weight | 200kg |
Test Items for Charging and Discharging Testing Equipment for New Energy Electric Vehicles
DC charging and interoperability test | 1. DC charging process test (routine charging test) | Vehicle charging and mode interlocking test |
| Connection confirmation test | ||
| Self-test phase test | ||
| Charging Readiness Test | ||
| Charging phase test | ||
| Normal charging ended test | ||
| 2. DC charging continuous control timing test (optional) | Charging connection control timing test | |
| 3. DC charging abnormal state test | Insulation fault test | |
| Communication interruption test | ||
| PE pin breakage test | ||
| Other charging fault tests | ||
| 4. Controlled pilot voltage boundary value test | Test of boundary voltage value at test point 2 | |
| Auxiliary power supply boundary voltage test | ||
AC charging and interoperability test | 1. AC charging process test (routine charging test) | Vehicle charging and mode interlocking test |
| Connection confirmation test | ||
| Charging Readiness Test | ||
| Startup and charging phase test | ||
| Normal charging ended test | ||
| 2. AC charging continuous control timing test (optional) | Charging connection control timing test | |
| 3. AC charging abnormal state test | Switch S3 disconnect test | |
| CC circuit breaker test | ||
| CP circuit breaker test | ||
| 4. AC control output test | PWM duty cycle change test | |
| PWM duty cycle over-limit test | ||
| PWM frequency boundary value test | ||
| 5. AC control loop testing | CP circuit boundary voltage test | |
| CC circuit boundary resistance value test | ||
| Discharge function test | AC charging port discharge power detection function | |
Technical Parameters of Charging and Discharging Testing Equipment for New Energy Electric Vehicles
| Project | Parameter |
| Input voltage range | 380VAC~485VAC |
| DC charging rated output maximum voltage | 1000VDC |
| Maximum output power of DC charging | 30kW |
| Maximum output current for DC charging | 100A |
| Maximum output power of DC charging | 30kW |
| AC charging voltage range | 0-305VAC |
| Maximum output current for AC charging | 32A |
| Maximum output power of AC charging | 7kW |
| AC charging frequency adjustment range | 45-70Hz |
| AC discharge power range | 1-7kW adjustable |
Parameter list
| Project | Specification |
| Equipment power supply | AC380V±10% 50Hz |
| Ambient temperature | -5~40℃ |
| Ambient humidity | Not exceeding 75% RH (no water vapor condensation) |
| Equipment size | 800*800*1750 (W*D*H excluding air conditioning) |
| Equipment weight | 200kg |