The AIP96 series AC/DC hi-pot insulation tester integrates AC hi-pot, DC hi-pot and insulation resistance testing, with a maximum output of 6000V. It features high precision, high speed and IEC/UL safety standards, and is widely used in electrical safety testing of motors, home appliances and electronic components.
■ Simple operation: Measurement results are displayed in real time, and parameters can be freely set;
■ Safety warning: Preset upper and lower limits for breakdown current, intelligent judgment, and audible and visual alarms;
■ Intelligent control: Employs CPU technology to precisely control the current boosting process;
■ Dual-frequency output: Supports AC 50/60Hz dual-frequency output;
■ Multiple protections: Features automatic overvoltage and overcurrent protection;
■ User interface: Features a high-definition LCD display and a simple panel operation;
■ Industry Standards: Meets the requirements of general electrical safety standards such as CCC, IEC, EN, VDE, BS, GS, and UL.
■ Three-in-one safety testing: It integrates AC hi-pot (ACW), DC hi-pot (DCW), and insulation resistance (IR) testing into one device, meeting multiple electrical safety testing requirements.
■ High-precision and high-speed measurement: It has high-precision and high-speed testing capabilities, and can accurately detect key parameters such as breakdown voltage, leakage current and insulation resistance.
■ Intelligent CPU Control: Employs high-performance CPU digital control technology to precisely control the voltage and current boosting process, ensuring test stability and repeatability.
■ Dual-frequency withstand voltage output: Supports AC 50Hz/60Hz dual-frequency output to meet testing applications of different national and industry standards.
■ Multiple safety protections: Built-in automatic overvoltage and overcurrent protection and intelligent determination of upper and lower limits of breakdown current, equipped with audible and visual alarms to improve test safety.
■ High-definition LCD human-computer interaction: It adopts a high-definition LCD display to display test results in real time, supports free parameter setting, and is intuitive and convenient to operate.
■ Compliant with international safety standards: Meets international electrical safety testing standards such as CCC, IEC, EN, VDE, BS, GS, and UL, and is suitable for the global market.
| AC hi-pot | |
| Output voltage setting range | AC 200~5000V |
| Output voltage accuracy | ±(2% × set value + 3 characters) |
| Breakdown current measurement range | 0.10~20.0mA |
| Breakdown current accuracy | ±(2% × displayed value + 3 characters) |
| Breakdown current preset alarm range | Upper limit: 0.10~20.0mA; |
| Lower limit: 0.00~5.00mA | |
| Test time range | 0.5~999.9s |
| Test time range/resolution | 0.1s/step |
| DC hi-pot | |
| Output voltage setting range | 200 ~ 6000V |
| Output voltage accuracy | ±( 2 % × setting value + 5 characters) |
| Breakdown current measurement range | 0.10 ~ 5.00mA |
| Breakdown current accuracy | ±( 2 % × displayed value + 5 characters) |
| Breakdown current preset alarm range | limit : 0.10~ 5.00mA |
| Lower limit: 0.00~5.00mA | |
| Test time range | 0.5~999.9s |
| Test resolution | 0.1s/step |
| Insulation resistance | |
| Output voltage setting range | DC 500/1000V |
| Output voltage accuracy | ±( 2 % × reading + 5 digits) |
| Insulation resistance measurement range | 1 ~ 2000MΩ |
| Insulation resistance accuracy | ≤100MΩ ±(5% × displayed value + 3 characters) |
| >100 MΩ ±(8% × displayed value + 8 characters) | |
| Insulation resistance alarm setting range | Upper limit: 0 ~ 2000MΩ |
| Limit: 1~ 2000MΩ | |
| Test time range | 0.5~999.9s |
| Test resolution | 0.1s/step |
| External dimensions | 280mm (W) × 89mm (H) × 430 mm (D) |
| Random accessories | Power cord ×1, high voltage rod ×1, return line ×1, fuse ×1, instruction manual ×1 |