The AIP three-phase AC frequency converter supports global grid simulation, with an output of 15–1200kVA. It features high-precision sine wave operation, three-phase decoupling control, soft start, and RS232/RS485 communication, making it suitable for motor, home appliance, medical, and certification testing applications.
■ The product has an advanced design concept, adopts modular design and digital control technology, has high stability, high precision, fast response speed, and human-machine interface and operation that conform to industry habits.
■ The product adopts three-phase decoupling control, which can adapt to 0-100% load imbalance.
■ It adopts precise anti-impact technology and can withstand the impact of large load current. It can withstand 3 times the rated current for 2 seconds, which is especially suitable for impact-type equipment such as motors and electric motors.
■ It has a soft start function, and the soft start time can be set. It is suitable for frequent starting of motors and other equipment. The soft start time can be set according to the working conditions to reduce the inrush current.
■ Fast dynamic response speed, with voltage change response time within 20ms.
■ The output voltage and frequency are adjustable in the startup state, making it flexible to use.
■ An 8-inch color LCD touchscreen with an exquisite appearance and convenient operation, equipped with numeric keys, function keys, and knobs for diverse operation.
■ It has an Auto-Lock function, which automatically locks the keyboard at regular intervals to prevent accidental contact that could lead to human error or danger.
■ Voltage range design: 0.0 ~ 150.0V, 150.1 ~ 300.0V, or 0.0 ~ 300.0V, both high and low ranges can output full power; frequency output range 45.00 ~65.00Hz, resolution 0.01Hz.
■ Built-in electrical parameter analysis function, capable of measuring parameters such as voltage, current, peak current, frequency, active power, apparent power, power factor, and peak voltage factor.
■ Equipped with a " black box " function, it monitors internal parameters such as voltage, current, and temperature in real time. In case of abnormality, it immediately alarms and automatically records the operating parameters for easy review and maintenance later.
■ Standard communication interface is RS232, with optional RS485, LAN , etc.
■ Global Three-Phase Power Grid Simulation – Simulates global three-phase voltage and frequency environments to meet international standard testing requirements.
■ Three-phase decoupling control technology – Supports 0–100% three-phase load imbalance, ensuring stable output and more accurate testing.
■ High impact load capacity – can withstand 3 times the rated current for 2 seconds, suitable for impact loads such as motors and compressors.
■ Adjustable soft start function – effectively reduces starting inrush current and improves equipment protection performance.
■ 20 ms high-speed dynamic response — quickly stabilizes the output voltage and adapts to transient load changes.
■ Built-in electrical parameter analysis – Real-time measurement of parameters such as voltage, current, frequency, power, and power factor.
■ Black Box Data Logging – Automatically records operating data and fault information, facilitating diagnosis and maintenance.
■ Intelligent Control and Communication – 8-inch touchscreen, standard RS232, supports RS485/LAN automation integration.
| Product Name | Three-phase AC frequency converter power supply | |||||||||
| Product Model | AIPFC015T | AIPFC0 30 T | AIPFC0 45 T | AIPFC0 60 T | AIPFC0 90 T | AIPFC 120 T | AIPFC 150 T | AIPFC 180 T | AIPFC 240 T | |
| Output capacity | 15kVA | 30kVA | 45kVA | 60kVA | 90kVA | 120kVA | 150kVA | 180kVA | 240kVA | |
| Basic functions | ||||||||||
| Output function | Simulate the voltage of power grids in various countries around the world | |||||||||
| Isolation function | Built-in isolation transformer | |||||||||
| Wiring method | Input: Three-phase four-wire; Output: Three-phase four-wire + PE | |||||||||
| Output parameters | ||||||||||
| Output mode | Three-phase standard sine wave | |||||||||
Output Voltage | Automatic transmission | Phase voltage: Low range: 0.0~150.0V Rated voltage: 1 1 0.0V High-end: 150.1~300.0V Rated voltage: 220.0V | ||||||||
| High-end lock | Phase voltage: 0.0~300.0V Rated voltage: 22 0.0V | |||||||||
| Voltage setting accuracy | ≤0.4 % FS Resolution: 0.1V | |||||||||
Rated Current | low-end | 45.4A | 90.9A | 136.3A | 181.8A | 272.6A | 363.6A | 454.5A | 545.4A | 727.2A |
| Upscale | 22.7A | 45.4A | 68.1A | 90.9A | 136.3A | 181.8A | 227.2A | 272.7A | 363.6A | |
| Output frequency | 45.00~65.00Hz | |||||||||
| Frequency setting accuracy | Accuracy: ≤0.02% Resolution: 0.01Hz | |||||||||
| Frequency stability | ≤0.02% | |||||||||
| Voltage distortion (V THD ) | <1% (linear load) | |||||||||
| Reaction time | ≤2ms | |||||||||
| Voltage change response time | ≤20ms | |||||||||
| Three-phase phase angle | 120°±2° | |||||||||
| Crest factor | 1.41±0.1 | |||||||||
| Source voltage effect | ≤1% | |||||||||
| Load effect | ≤1% | |||||||||
| Efficiency | >85% | |||||||||
| Measurement display | ||||||||||
| Display mode | 8-inch color LCD screen | |||||||||
| Voltage measurement accuracy | Accuracy: 0.2%FS + 0.2% Display value resolution: 0.1V | |||||||||
| Frequency measurement accuracy | Accuracy: 0.02% Resolution: 0.01Hz | |||||||||
| Current measurement accuracy | Accuracy: 0.3%FS + 0.3% Display value resolution: 0.1A/1A | |||||||||
| Power measurement accuracy | Accuracy: 0.5%FS + 0.5% Display value resolution: 0.1kW/0.01kW/0.001kW | |||||||||
| Function Operation | ||||||||||
| Automatic memory function | The settings are automatically remembered and automatically recalled upon startup. | |||||||||
| Soft start | It features a soft-start function, with the soft-start time adjustable from 0.0 to 99.9 seconds. | |||||||||
| Real-time adjustment function | In the startup state, the output voltage and frequency settings can be adjusted and updated instantly using the numeric keys, increment/decrement keys, and knob. | |||||||||
| Voltage drop compensation function | Impedance compensation: 0.000~0.500 ohms | |||||||||
| Quick access | 10 quick groups in normal mode | |||||||||
| Protection function | ||||||||||
| Overload capacity | Output will be cut off after 15 seconds if the load is between 105% and 110% overload. Output cut off after 5 seconds if 110% < overload ≤ 200%. Output cut off after 2 seconds if 200% < overload ≤ 300%. Output will be immediately cut off if the overload exceeds 300%. | |||||||||
| Protective devices | Overcurrent, overload, and short circuit protection; overheat protection; output over/under voltage and phase loss protection. | |||||||||
| Software protection | AI-Monitor function, Black-Box function, Auto-Lock key lock protection | |||||||||
| Remote Interface | ||||||||||
| Communication interface | RS232 (standard) , RS485, LAN (optional) | |||||||||
| Input parameters | ||||||||||
| Input number of phases | Three-phase four-wire + PE | |||||||||
| Input voltage range | 380V±57V | |||||||||
| Input frequency range | 45~65Hz | |||||||||
| Work environment | ||||||||||
| Operating temperature | 0~40℃ | |||||||||
| Operating humidity | 20–90% RH (non-condensing) | |||||||||
| Volume and weight | ||||||||||
| Dimensions (W×H×Dmm) | 600×1150×1020 | 700×1350×1220 | 800×1750×1420 | |||||||
| Weight (Kg) | 265 | 310 | 440 | 550 | 740 | 980 | 1250 | 1270 | 1400 | |
| Product Name | Three-phase AC frequency converter power supply | ||||||
| Product Model | AIPFC 350 T | AIPFC 450 T | AIPFC 550 T | AIPFC 650 T | AIPFC 800 T | AIPFC 1000 T | AIPFC 1200 T |
| Output/Absorption Capacity | 350 kVA | 450 kVA | 550 kVA | 650 kVA | 800 kVA | 1000 kVA | 1200 kVA |
| Basic functions | |||||||
| Output function | Simulate the voltage of power grids in various countries around the world | ||||||
| Isolation function | Built-in isolation transformer | ||||||
| Wiring method | Input: Three-phase four-wire; Output: Three-phase four-wire + PE | ||||||
| Output parameters | |||||||
| Output mode | Three-phase standard sine wave | ||||||
| Output voltage | Phase voltage: 0.0~300.0V; Rated voltage: 220.0V | ||||||
| Voltage setting accuracy | ≤0.4 % FS Resolution: 0.1V | ||||||
| Rated current | 454.5A | 606.0 A | 757.5 A | 909.0 A | 1212.1A | 1515.1A | 1818.1A |
| Output frequency | 45.00~65.00Hz | ||||||
| Frequency setting accuracy | Accuracy: ≤0.02% Resolution: 0.01Hz | ||||||
| Frequency stability | ≤0.02% | ||||||
| Voltage distortion (V THD ) | < 3 % (linear load) | ||||||
| Reaction time | ≤2ms | ||||||
| Voltage change response time | ≤20ms | ||||||
| Three-phase phase angle | 120°±2° | ||||||
| Crest factor | 1.41±0.1 (sine wave mode) | ||||||
| Source voltage effect | ≤1% | ||||||
| Load effect | ≤1% | ||||||
| Efficiency | >85% | ||||||
| Measurement display | |||||||
| Display mode | 8-inch color LCD screen | ||||||
| Voltage measurement accuracy | Accuracy: 0.2%FS + 0.2% Display value resolution: 0.1V | ||||||
| Frequency measurement accuracy | Accuracy: 0.02% Resolution: 0.01Hz | ||||||
| Current measurement accuracy | Accuracy: 0.3%FS + 0.3% Display value resolution: 0.1A/1A | ||||||
| Power measurement accuracy | Accuracy: 0.5%FS + 0.5% Display value resolution: 0.1kW/0.01kW/0.001kW | ||||||
| Function Operation | |||||||
| Automatic memory function | The settings are automatically remembered and automatically recalled upon startup. | ||||||
| Soft start | It features a soft-start function, with the soft-start time adjustable from 0.0 to 99.9 seconds. | ||||||
| Parameter settings are adjusted in real time. | In the startup state, the output voltage and frequency settings can be adjusted and updated instantly using the numeric keys, increment/decrement keys, and knob. | ||||||
| Voltage drop compensation function | Impedance compensation: 0.000~0.500 ohms | ||||||
| Quick access | 10 quick groups in normal mode | ||||||
| Protection function | |||||||
| Overload capacity | Output will be cut off after 15 seconds if the load is between 105% and 110% overload. Output cut off after 5 seconds if 110% < overload ≤ 200%. Output cut off after 2 seconds if 200% < overload ≤ 300%. Output will be immediately cut off if the overload exceeds 300%. | ||||||
| Protective devices | Overcurrent, overload, and short circuit protection; overheat protection; output over/under voltage and phase loss protection; bus over/under voltage protection; automatic tripping protection of output power contactor. | ||||||
| Software protection | AI-Monitor function, Black-Box function, Auto-Lock key lock protection | ||||||
| Remote Interface | |||||||
| Communication interface | RS232 (standard) , RS485, LAN (optional) | ||||||
| Input parameters | |||||||
| Input number of phases | Three-phase four-wire + PE | ||||||
| Input voltage range | 380V±57V | ||||||
| Input frequency range | 45~65Hz | ||||||
| Work environment | |||||||
| Operating temperature | 0~40℃ | ||||||
| Operating humidity | 20–90% RH (non-condensing) | ||||||
| Volume and weight | |||||||
| Dimensions (W×H×Dmm) | 18.00 × 2000 × 14.00 | 2400 × 2000 × 14 00 | 2400 × 2000 × 1850 | 3600 × 2000 × 1850 | 4800 × 2000 × 1400 | 4800 × 2000 × 1850 | |
| Weight (Kg) | 2100 | 3200 | 3500 | 4500 | 6400 | 7500 | |